INERGEK
INDUSTRIAL ENGINEERING & CONNECTIVITY
NUMERO DI PARTE
IBS310  
Cavo stabile di fase a bassa perdita (IPS)

Low loss Phase Stable Cable IBS310  

DISEGNO MECCANICO / DIMENSIONI (mm)

Construction Specification

  Item  Material  Diameter(mm)
  1. Inner Conductor   Silver Plated Copper   1.02
  2. Dielectric   LD PTFE   3.07
  3. Outer Conductor 1   Silver Plated Copper Tape Braid   --
  4. Outer Conductor 2   Aluminum foil   --
  5. Outer Conductor 3   Silver Plated Copper Tape Braid   4.06
  6. Jacket   FEP   4.57

Electrical Characteristics

  Capacitance(pF/m)   Nom.87.6
  Impedance(ohm)   50
  Velocity of Propagation(%)   76
  Time Delay(ns/m)   4.3
  Max Operating Frequency(MHz)   18
  Voltage Withstanding(kVrms 60Hz/1 min.)   1.0

Mechanical and Environmental Characteristic

  Operating Temp.(℃)   -55 to +200
  Min Bending Radius(mm)   25.4
  RoHS   Compliant

Attenuation & Average Power@ 20℃ at Sea Level

  Frequency(GHz)  Attenuation(dB/m)  Power(CW)
  0.1   0.11   1843
  0.4   0.23   912
  1.0   0.37   569
  2.0   0.51   397
  3.0   0.65   320
  8.0   1.08   189
  10.0   1.19   167
  12.0   1.33   151
  13.5   1.41   141
  16.0   1.55   128
  18.0   1.66   120
Avviso: INERGEK si riserva il diritto di apportare le modifiche ritenute opportune.