INERGEK
INDUSTRIAL ENGINEERING & CONNECTIVITY
NUMERO DI PARTE
ITX-75-2  
Cavo triassiale (ITX)

Tri-Coaxial Cable ITX-75-2  

DISEGNO MECCANICO / DIMENSIONI (mm)

TRC-75-2  More Products

  Item   Material   Diameter(mm)
  1. Inner Conductor   Tinned Copper   7X0.16
  2. Dielectric   PE   2.95
  3. Inner Braiding   Tinned Copper Braid   Nom.3.35
  4. Inner Jacket   PE   4.45
  5. Outer Braiding   Tinned Copper Braid   Nom.5.10
  6. Outer Jacket   Thermoplastic Elastomer   6.22
  Capacitance(pF/m)   Inner Conductor to Inner Braiding  Inner Braiding to Outer Braiding   67.26  332.35
  Impedance(ohm)     75
  Velocity of Propagation(%)     66
  Max Operating Voltage(Vrms)     2000
  Max Operating Frequency(MHz)     3000
  Operating Temp.(℃)   -40 to +80
  Bending Radius(mm)   32
  ROHS   Compliant
  Frequency(MHz)   Attenuation(dB/m)
  10   4.92
  20   7.55
  30   9.51
  40   10.83
  50   11.81
  100   17.06
  200   24.93
  500   35.43
  700   48.23
  1000   57.74
Avviso: INERGEK si riserva il diritto di apportare le modifiche ritenute opportune.
🌐 www.inergek.com    ✉ [email protected]    ☎ +86 189 7105 6957
INERGEK
INDUSTRIAL ENGINEERING & CONNECTIVITY
NUMERO DI PARTE
ITX-75-2  
Avviso: INERGEK si riserva il diritto di apportare le modifiche ritenute opportune.
🌐 www.inergek.com    ✉ [email protected]    ☎ +86 189 7105 6957